Hypertherm 45XP error code 3-10-1

Hypertherm Plasma Cutter discussion forum.
Post Reply
User avatar
tinspark
3.5 Star Elite Contributing Member
3.5 Star Elite Contributing Member
Posts: 702
Joined: Wed May 30, 2018 4:28 pm

Hypertherm 45XP error code 3-10-1

Post by tinspark »

I just got the dreaded error code 3-10-1 on my Hypertherm Powermax 45xp (non-sync) today.
I couldnt hear any fan rattling or noise until I shut the compressor off and all shop noise.
The little fan was on its last leg. My shop is so noisy I cannot hear the fan or any fan noise
Pulled the fan out and ordered another one.

I did put it back together with the old fan and it does work but is hobbling along. and rattling like a honeymoon car dragging stringed cans down the road!
But I will hold off on cutting anything until the new fan comes.
We are still in the hot season here in central CA, USA and I do not want to fry a board or anything else because of a $65.00 fan....
I have worked this little plasma cutter hard over the last 6 years and have no complaints!
Doug,
4x4 GoTorch- expanded
Height Control/Advanced DesignEdge
Hypertherm 45XP-
Logan Lathe + myriads of other shop toys
**CAUTION**- "Does Not Play Well With Others" :)
05Duramax
1.5 Star Member
1.5 Star Member
Posts: 31
Joined: Tue Jan 09, 2024 10:30 am

Re: Hypertherm 45XP error code 3-10-1

Post by 05Duramax »

Same issue here with me on my PM65 and the new fan fixed it. Didn't order mine from Hypertherm, I found the exact same fan online for a fraction of the cost. Hope the new fan solves your problem. Good luck.